![]() It can also be related to the arp resolution because I'm virtually connected to the remote host and I know its MAC address. How can I monitor a link from one server to another and take action if the link is down? I decided to rephrase my question because I feel like no one knows. So far I see different stuff like ip rule, heartbeat HA and other technologies but with this question, what I want to achieve is to determine if what I want to do is possible and if possible with what kind of technologies. I have no access to the routers, and no dynamic routing from outside A can be involved. What I want is to set up a failover route that tries to connect through eth1 if the connection attempt fails on eth0. In the routing table A, B is reachable through interface eth0. eth0 has a public IP and connects directly to a remote server (let's call it B), the second interface of A, eth1 is on a local network with another internet connection supposed to be used for different purpose. There is no default gateway and only a few servers are statically reached from A. I have a Debian Wheezy server running Xivo (let's call it A), this server has 2 interfaces: Sample output – help menu Getting SDR records. Rko iKVM remote keyboard operation(X9 or later) Rsc iKVM remote screen capture(X9 or later) ext:png|jpg Nvme NVMe (Non-Volatile Memory Express) (8) Wsiso Mount ISO file via Windows Share or SAMBA (for X9 and later) (3) Prompt Config information displayed on prompt Kvmwx9 SIM(X9) KVM console (graphic mode) List List all or find available commandsĮxec Execute commands from fileĮxecm Execute commands from file for TaskRunįind Find IPMI device from local or IP range Nm30 Node Management V3.0 (Grantley platform or later) (10) Nm20 Node Management V2.0/V3.0 (Romley platform or later) (42) Microblade MicroBlade & 8U/4U SuperBlade blade management (6) Superblade SuperBlade blade management (13) SUSE Linux Enterprise Server (SLES) 11 or later.Red Hat Enterprise Linux (RHEL) 6.8 or later,.Remote Screen Capture (Node Product Key is required).Virtual Media Management (Node Product Key is required).System Diagnostic (w/ Super Diagnostics Offline).This utility can be easily integrated with existing infrastructure to connect with Supermicro servers’ baseboard management controllers (BMCs). This utility provides two user modes, viz.: OS Command Line Mode and Shell Mode. The SMCIPMITool is an Out-of-Band Supermicro utility that allowing users to interface with IPMI devices, including SuperBlade ® systems, via CLI (Command Line Interface). Status | (#)Sensor | Reading | Low Limit | High Limit Sample output – help menu > IPMICFG.exe –sdr If VLANtag is not given it uses previously saved value. vlan on Enable the VLAN and set the VLAN tag. Option: -d | Detected IPMI device for BMC reset. k Mask Set Subnet Mask (format: #.#.#.#). Usage: IPMICFG params (Example: IPMICFG -m 192.168.1.123) Ex: Red Hat Enterprise Linux (RHEL) 6.8 and 7.2 SUSE Linux Enterprise Server (SLES) 11 SP4 and 12 SP1 Ubuntu Server 14.04 LTS and 16.04 LTS ![]() Supermicro Baseboard Management Controller (BMC) must support Intelligent Platform Management Interface (IPMI) version 2.0 specifications.Manage IPMI by node management (NM) protocol.Data Center Solution Engineering (DCSE).
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |